Advantage stationary gas detector for measuring concentrations of explosive toxic gases, oxygen, carbon dioxide, sulfuric acid, alkali, and volatile organic compounds in the air of the work area. It is used to provide a warning signal when the set thresholds are exceeded.

Thanks to the frostproof OLED display, the gas detector can be used in harsh Russian climatic conditions.

It is issued according to the 26.51.53.110-007-56795556-2019

Advantages of Advant:

Easy to use:
  • Easy to install and easy to use

  • Setup and verification at the installation location

  • Bright LED indication of the operating mode

  • Prompt service

  • Multi-function screen

  • Visual and audible alarm (optional)

  • The ability to connect to a radio channel (optional)
High reliability:
  • 100% quality control
  • Compliance with regulatory documents: State Standard, technical regulations, EU directives, etc.
  • Environmental resistance, protection against poisoning
Measurement accuracy:
  • Sensitivity to low gas concentrations
  • High stability of indication
  • Low error values
Investment efficiency:
  • Service life - at least 15 years
  • Free configuration software
  • On-site calibration (reduced maintenance costs)
  • The possibility of obtaining an extended warranty of up to 5 years (optional)
The frostproof OLED-display:
  • The operating temperature of the display is from -60 to +65 °C
  • Simultaneous display of the current concentrations of the measured gases
  • Intuitive setting/ easy to use
  • Choice of measurement units (ppm and mg/m3)
Simultaneous use of two sensors:
  • Quick sensor replacement
  • Easy maintenance
  • Adaptive sensor heating

Related devices for Advant:

SGM ERIS-130 - Multi-channel controller https://eriskip.com/en/product/sgm-eris-130

ERIS-2100 - Programmable measuring controller https://eriskip.com/en/product/Контроллеры%20измер...

The verification interval is 1 year

The warranty period for the device is 36 months from the date of purchase of the device.

The warranty period for the sensor is 12/36 months (depends on the type).

The sensors can be installed indoors and outdoors in zones 1 and 2.

The built-in display shows the current concentration directly at the installation location of the gas detector..

Advant gas detectors are characterised by low energy consumption and the ability to operate in extreme climatic conditions. There is no need to install two gas detector sensors if there is a need to measure different types of gases or volatile organic compounds.

Maintenance of the device is facilitated by software troubleshooting tools, as well as the included magnetic key.

The main technical characteristics of the Advant 2:

Modifications
  • Advantage IR (with infrared optical sensors)
  • Advantage CT (with catalytic bead sensors)
  • Advantage EC (with electrochemical sensors)
  • Advantage PID (with photoionisation sensors)
Interfaces:
  • Analog 4-20 mA
  • Digital RS-485/ Modbus RTU
  • Digital HART (optional)
  • Digital HART with local connector (optional)
  • Bluetooth connection for device configuration (optional)
Type of explosion protection:
  • 1Ех db [ia Ga] IIC T6 Gb X
  • Ех tb [ia Da] IIIC T80°С Db X
  • 1Ех db IIC T6 Gb X
  • Ех tb IIIC T80°С Db X
Protection from dust and moisture:
  • IP66/ IP67
Supply voltage, V:
  • basic: 24
  • Acceptable range: 12-36
Service life, years, not less:
  • 12
Average time to failure, hours (depending on sensor type):
  • IR: 70000
  • CT: 35000
  • EC: 35000
  • PID: 35000
Ambient and analyzed media temperature range, deg.C:
  • For IR, CT, and PID sensors from -60 to +65
  • For EC: -40 to +50
Relative humidity, %, max:
  • 98
Atmospheric pressure range, kPa:
  • from 84 to 106.7
Verification interval:
  • IR: 1 year
  • CT: 1 year
  • EC: 1 year
  • PID: 1 year
Warranty period (from the day of purchase):
  • 36 months per device
  • 36 months IR sensor
  • 12 months sensors: CT, EC, PID
Main delivery package:
  • Gas detector Advant
  • Magnetic key
  • Passport
  • Method of verification
  • User manual
Additional equipment on request:
  • Calibration cap
  • Pipe mounting package
  • Air duct mounting package
  • Protective visor from sun and rain
  • Insect protection cap
  • Cabel gland
  • Stopping plugs
  • Connector for HART communicator
  • Visual and Audible Alarm
Approved measurement accuracy for oil vapours :
  • Exists
List of detected gases:
Advant IR CT:
  • Petroleum and oil vapours
  • Acetic acid (CH3OOH)
  • Methane (CH4)
  • Ethane (C2H6)
  • Propane (C3H8)
  • Butane (C4H10)
  • Isobutane (i-C4H10)
  • Pentane (C5H12)
  • Cyclopentane (C5H10)
  • Hexane (C6H14)
  • Cyclohexane (C6H12)
  • Propene (Propylene) (C3H6)
  • Methanol (CH3OH)
  • Ethanol (C2H5OH)
  • Heptane (C7H16)
  • Ethylene (C2H4)
  • Ethylene oxide (C2H4O)
  • Benzene (C6H6)
  • Carbon dioxide (CO2) (DGS ERIS-230IR only)
  • Hydrogen (H2) (DGS ERIS-230SAT)
  • Amyl
  • Acetylene
  • Acetone
  • Acetaldehyde
  • Diesel fuel according to the standart (GOST 305-2013)
  • White spirit according to the standart (GOST 3134-78)
  • Jet fuel according to the standart (GOST 10227-86)
  • Car gasoline
  • Aviation gasoline according to the standart (GOST 1012-2013)
  • Gas condensate
  • Unleaded gasoline
  • Kerosene according to the technical terms standart 38.71-5810-90
  • Butadiene -1,3
  • Butylenes
  • Butyl alcohol, butanol
  • Gases hydrocarbon liquified
  • Divinyl
  • Dioxane
  • Diethyl ether
  • Isobutyl alcohol, isobutanol
  • Isobutylene
  • Isopropanol
  • Isoprene
  • Methanol
  • Metiletilkenton, ethyl methyl ketone
  • Propylene oxide
  • Ethylene oxide
  • Acetic acid
  • Formaldehyde
Advant EC:
  • Sulfuric acid (Н2SO4)
  • Sodium hydroxide(NaOH)
  • Nitric acid (HNO3)
  • Sodium hypochlorite( ClNaOH)
  • Hydrogen sulfide (H2S)
  • Ethylene oxide (C2H4O)
  • Hydrazine (N2H4)
  • Hydrogen chloride (HCL)
  • Hydrogen fluoride (HF)
  • Ozone(O3)
  • Silane (SiH4)
  • Nitric oxide(NO)
  • Nitrogen dioxide(NO2)
  • Ammomia(NH3)
  • Hydrogen cyanide (HCN)
  • Carbon monooxide(CO)
  • Chlorine (Cl2)
  • Sulfur dioxide(SO2)
  • Oxygen(02)

Advant PID:
  • Vinyl chloride
  • Benzene
  • Propanol
  • Styrene
  • Ethanol
  • Bytanol
  • Methalon
  • Toulol (toluene)
  • Phenol
  • Xylene
  • Arsine
  • Phosphine
  • Epichlorohydrin
  • Monoethanolamine
  • Diethylamine
  • Butyl acrylate
  • N-Propylacetate
  • Ethylene oxide
  • Chlorine dioxide
  • Diethylamine
  • Triethylamine
  • Ethylbenzene
  • Isobutylene
  • N-Dimethylacetamide
  • Monoethylene glycol
  • Diethylene glycol
  • Ethyl chlorformiate
  • 2-ethylhexylamine
  • Sulphur hexafluoride
  • Chlorinated gasoline
  • Furfuryl alcohol
  • Acetic acid
  • Acrylic acid