DGS ERIS-PID

roll over image to zoom in

DGS ERIS-PID has a wide list of the gases being measured, perfectly suited for operation in a wide temperature range, it has an intuitive interface that reduces setup time and maintenance.

The integrated display shows the current concentration directly at the place of installation of the gas analyzer.

The advantages of the gas analyzer:

  • Measurement of wide range of VOC's
  • Setup and Calibration at the place of operation, including in the hazardous area, using a magnetic key or manual interrogator
  • Continuous self-diagnostics
  • Display and bright LED indication
  • The low level of errors
  • Low response time
  • Available modification with a wireless data transmission and battery-powered modification
  • Versions in aluminum or stainless steel housing
  • Ability to work both as part of systems and independently
  • Suitable for wide range climatic zones
  • Adaptive heated measuring element
  • Built-in protection against false readings
  • Protection from the effects of dust and water
  • The grounding contacts
  • Built certified software with protection level "C"

Main specifications:

Housing
  • Aluminium, painted bright colour epoxy paint
  • Steel grade AISI 316L analogue 03H16N15M3
Output signals
  • 4-20 mA
  • RS-485/Modbus
  • HART (optional)
  • HART with a local socket for intrinsically safe connection (optional)
Relays 3 relays (optional):
Alarm 1, Alarm 2, Fault (220V, 2,5A)
Ex 1 Ex d [ia] IIC T6 X
IP rating IP67
Rated supply voltage, V
  • Nominal: 24
  • The range of input voltage: 18-36
Power consumption, W, no more 2
Average service life, years, not less 12
Mean time between failures, h 35000
The range of ambient temperature and analyzed environments, °C from -60 to 65
Relative humidity,%, no more 98
Atmospheric pressure range, kPa от 84 до 106,7
Verification interval, years 1
Verification interval, years1
The basic package
  • Gas detector
  • Magnetic key
  • Passport
  • User Manual
Additional equipment on request
  • Calibration cap
  • Pipe mounting kit
  • Duct mounting kit
  • Sunshade/deluge protection
  • Cable entry
  • Cable entry plug
List of measured gases
  • Vinyl chloride
  • Benzene
  • Propanol
  • Styrene
  • Ethanol
  • Butanol
  • Methanol
  • Toluene
  • Phenol
  • Xylol
  • Arsine
  • Phosphine
  • Epichlorohydrin
  • Monoethanolamine
  • Diethanolamine
  • Butyl acrylate
  • N-propyl
  • Ethylene oxide
  • Chlorine dioxide
  • Diethylamine
  • Triethylamine
  • Ethylbenzene
  • Isobutylene
  • N-dimethylacetamide
  • Mono-ethylene glycol
  • Diethylene glycol
  • Ethyl chloroformate
  • 2-ethylhexylamine
  • Sulfur hexafluoride
  • Benzyl chloride
  • Furfuryl alcohol
  • Acetic acid
  • Acrylic acid
  • Sulfuric acid